Cyclone Separator: flat pattern

A cyclone dust collector from its barrel diameter, to Stairmand or Lapple proportions or your own: barrel, cone, roof, inlet duct and gas outlet tube. A cyclone dust collector from its barrel diameter, to the Stairmand or Lapple proportions or your own: the barrel with the inlet opening, the cone, the roof with the hole for the gas outlet, the inlet duct and the gas outlet tube.

Open the cyclone separator in SheetMorph

Configurations

A worked example

The stairmand (high efficiency) configuration with the sizes SheetMorph opens with, in mm. Five plates: the cone, the barrel with the inlet opening, the roof, the inlet duct and the gas outlet tube: 5 parts, 8 seams.

The flat pattern of this example: outlines to cut, with the lines to mark and any holes. Open it in SheetMorph for the dimensioned drawing and the files to cut it.
For the shop
Blank of P11838.0 mm × 1579.8 mm
Blank of P21885.2 mm × 900.1 mm
Blank of P3598.1 mm × 599.0 mm
Blank of P4844.0 mm × 400.0 mm
Blank of P5944.1 mm × 450.0 mm
Length of cut, every outline and hole18785.5 mm
Sizes
Inlet height300.00 mm
Inlet width120.00 mm
Gas outlet diameter300.00 mm
Gas outlet depth below the roof300.00 mm
Barrel height900.00 mm
Cone height1500.00 mm
Height, dust outlet to roof2400.00 mm
Dust outlet diameter225.00 mm
Areas
Inlet36,000 mm²
Gas outlet70,686 mm²
Barrel
Girth of the plate1888.10 mm
Width of the inlet opening, round the barrel279.65 mm
Angle the opening spans53.13 °
Depth of the opening, from the top301.00 mm
Cone
Slant height1511.67 mm
Outer radius of the flat sector2422.71 mm
Angle of the flat sector44.65 °
Inlet duct
Inner wall meets the barrel this far back241.00 mm
Length of the inner wall159.00 mm
Girth of the plate844.00 mm
Gas outlet tube
Length450.00 mm
Girth of the plate945.62 mm
Plate blanks
P1 Cone, long1838.04 mm
P1 Cone, wide1579.77 mm
P2 Barrel, long1885.21 mm
P2 Barrel, wide900.06 mm
P3 Roof, long598.10 mm
P3 Roof, wide599.02 mm
P4 Inlet duct, long844.00 mm
P4 Inlet duct, wide400.00 mm
P5 Gas outlet tube, long944.10 mm
P5 Gas outlet tube, wide450.00 mm
Pattern
Plates5
Triangular facets254
Pattern extent X7994.66 mm
Pattern extent Y1579.77 mm
Area of the blanks4,504,638 mm²
Area cut out71,129 mm²
Net area4,433,508 mm²
Total cut length19731.02 mm
Longitudinal seam length3020.68 mm

How it is developed

Development of rolled plates (barrel, cone, tube) and flat and folded plates (roof, inlet duct). This is an exact development: the surface unfolds without stretching, so the pattern closes exactly.

Checked before it can be exported

Every pattern SheetMorph draws is checked against the 3D part it comes from. For this example:

Assumptions

Limits of this module

Conventions

Coordinate system. The part stands on the Z axis with End A at Z = 0. Angles round the axis are measured from +X toward +Y, counter-clockwise seen from +Z.

Divisions and thickness. A circle is divided into 4N equal chords. Sizes are inside, mid-thickness or outside sizes; the pattern is developed on the mid-thickness surface and the views show the sizes as entered.

Body. The cyclone stands on the Z axis with the dust outlet, the foot of the cone, at Z = 0. The cone rises to the barrel, the barrel to the roof, and the gas outlet tube passes down through the roof to its foot inside the barrel.

Inlet. The inlet is a rectangular duct that enters along the barrel: its outer wall touches the barrel on +X, its top is level with the roof, and it runs toward -Y, so the air turns counter-clockwise seen from above. Its length is measured along it from the line where its outer wall touches the barrel.

Proportions. Stairmand and Lapple are the two standard proportions found in air pollution control references, each size a multiple of the barrel diameter D. They are starting points: the efficiency and pressure drop of a cyclone depend on the dust, the flow and the speed at the inlet, which are not worked out here.

Plates. The barrel is one plate with the inlet opening cut in its top; it and the cone are cut on the side opposite the inlet. The roof is flat, with the hole for the gas outlet tube. The inlet duct is one plate folded at its four corners, its end against the barrel cut to the barrel.

Change the sizes to your own in SheetMorph, check the drawing, add seam and flange allowances, and export DXF, PDF, SVG, CSV or G-code. Check every pattern against your own standards before cutting.

Open the cyclone separator

Other hoods, plenums and cyclones